ThermCable Extension Cables are comparable to electrical cables
The component „conductor“ is single-wire or can be up to 8 leads. These leads can be made of the following materials: Cu, Ni, CuNi or Stainless Steel.
The standard insulation is MgO. According to demand, SiO2 or Al2O3 can be used. Contrary to sheathed cables (for thermocouples) mineral-insulated cables are used as extender for resistance thermometers.
Temperature range depending on conductor and sheath material starts at low temperatures up to 1000°C.
The range of diameters varies from 0.5mm to 8mm.

DELIVERY PROGRAM
Standard Delivery Program MineraI-Insulated Extension Cables
Standard Delivery Program MineraI-Insulated Extension Cables
Outer sheath material: e.g Inconel 600 2.4816 Stainless steel 1.4541, 1.4571, 1.4404, 1.4301, etc.
Special materials upon customer request!
Mineral Insulated RTD 8-core Standard range
Special geometries (core diameter, wall thickness, etc.) according to customer requirements
Sheath: Inconel 600 (2.4816)or stainless steel 1.4541, 1.4571, 1.4404, 1.4306, etc.
Core material: copper or nickel
Other core materials like Cu with nickel-plated or copper-zirconium with stainless steel plated upon request.
Mineral Insulated RTD 6-core Standard range
Special geometries (core diameter, wall thickness, etc.) according to customer requirements
Sheath: Inconel 600 (2.4816)or stainless steel 1.4541, 1.4571, 1.4404, 1.4306, etc.
Core material: copper or nickel
Core materials like Cu with nickel-plated or copper-zirconium with stainless steel plated upon request.
Mineral Insulated RTD 4-core Standard range
Special geometries (core diameter, wall thickness, etc.) according to customer requirements
Sheath: Inconel 600 (2.4816) or stainless steel 1.4541, 1.4571, 1.4404, 1.4306, etc.
Core material: copper or nickel
Core materials like Cu with nickel-plated or copper-zirconium with stainless steel plated upon request.
Mineral Insulated RTD 2-core Standard range
Special geometries (core diameter, wall thickness, etc.) according to customer requirements
Sheath: Inconel 600 (2.4816)or stainless steel 1.4541, 1.4571, 1.4404, 1.4306, etc.
Core material: copper or nickel
Core materials like Cu with nickel-plated or copper-zirconium with stainless steel plated upon request.
subject to errors
COMPANY ADRESS
ThermCable GmbH
Am Bahnhof 6a
63505 Langenselbold
Phone +49(0) 61 84 / 9 32 84 – 0
Fax +49(0) 61 84 / 9 32 84 – 11
Email: info@thermcable.de
Web: www.thermcable.com
OUR QR-CODE
Scan our QR code with your app. Our website on your mobile device.
Quick-Navigation
CERTIFICATES
We are certified:
To open the files you need Adobe Acrobat Reader (free download here)